Soudaduct
Soudaduct
Soudaduct is a high-quality, plasto-elastic, solvent free HVAC ducting sealant for all types of metal ducts.
Technical data sheet
Declaration of Performance
- Very easy to apply
- Low odour and solvent free
- Colour-fast and water-proof after curing
- Very good adhesion on galvanised and stainless steel
- Remains permanently flexible
- Conforms to Class C of DW144 and ISO11600 Class 12.5P
- Low odour and solvent free
- Colour-fast and water-proof after curing
- Very good adhesion on galvanised and stainless steel
- Remains permanently flexible
- Conforms to Class C of DW144 and ISO11600 Class 12.5P
- All types of HVAC duct systems including sheet metal, duct board and flexible ducts
- Sealing of seams, spigot and flange joints and metal fabrications
- Joints with movements up to 15%.
- Sealing of seams, spigot and flange joints and metal fabrications
- Joints with movements up to 15%.
Type: concrete, metal, bricks
State of Surface: clean, free of dust and grease
Preparation: slight moistening of the surface increases adhesion
We recommend a preliminary compatibility test.
State of Surface: clean, free of dust and grease
Preparation: slight moistening of the surface increases adhesion
We recommend a preliminary compatibility test.
Method: Apply the sealant by means of a brush, handheld or pneumatic caulking gun. Spread a minimum of 20 mm wet film thickness with a brush,
or pump into well fitted joints. Seal all joints, seams, and penetrations in the ductwork to ensure an airtight system.
Application temperature: +5°C to +30°C
Clean: Uncured Soudaduct may be removed from tools with water. Cured sealant must be removed mechanically.
Repair: with Soudaduct
or pump into well fitted joints. Seal all joints, seams, and penetrations in the ductwork to ensure an airtight system.
Application temperature: +5°C to +30°C
Clean: Uncured Soudaduct may be removed from tools with water. Cured sealant must be removed mechanically.
Repair: with Soudaduct
- Do not use in applications where continuous water immersion is possible.
- Do not apply when rain or frost is imminent
- Soudaduct can be painted over with most paints.
- The paint should be sufficiently elastic to be applied on a plasto-elastic sealant.
A preliminary test is recommended.
- Prior to pressure testing allow 12 – 24 hours drying time depending on temperature, humidity and application thickness
- Do not apply Soudaduct outdoors
- Do not apply when rain or frost is imminent
- Soudaduct can be painted over with most paints.
- The paint should be sufficiently elastic to be applied on a plasto-elastic sealant.
A preliminary test is recommended.
- Prior to pressure testing allow 12 – 24 hours drying time depending on temperature, humidity and application thickness
- Do not apply Soudaduct outdoors